 "title": "Tent Wind & Anchoring Rules",
 "description": "Official tent anchoring, ballast and wind take-down rules for the 16 jurisdictions in the TentRentalHQ Permit Threshold Atlas, each quoted from the official page with a last-verified date. Blank where no official source states a rule.",
 "license": "https://creativecommons.org/licenses/by/4.0/",
 "license_name": "CC BY 4.0",
 "attribution": "TentRentalHQ (https://tentrentalhq.com/)",
 "last_verified": "2026-11-23",
 "last_verified_s": "November 23, 2026",
 "disclaimer": "Not legal or engineering advice and not an anchoring calculator. Rules are quoted from the official pages linked, as last verified on the date shown. A blank cell means we found no official text, not that no rule exists. Your installer's manufacturer specifications and the fire official on site decide.",
 "model_code": {
  "text": "IFC §3103.9 (numbered 3103.8 in some editions): “Tents or membrane structures and their appurtenances shall be designed and installed to withstand the elements of weather and prevent collapsing.” For air-supported structures, door use is controlled in winds over 50 mph (IFC §3103.10.1). The model fire code sets no evacuation wind speed for ordinary tents.",
  "source": {
   "title": "2021 Seattle Fire Code, Chapter 31 (IFC as amended)",
   "url": "https://www.seattle.gov/documents/Departments/SDCI/Codes/SeattleFireCode/2021SFCChapter31.pdf",
   "quote": "3103.9 Structural stability and anchorage required. Tents or membrane structures and their appurtenances shall be designed and installed to withstand the elements of weather and prevent collapsing. Documentation of structural stability shall be furnished to the fire code official on request.",
   "last_verified": "2026-11-22",
   "last_verified_s": "November 22, 2026"
  }
 },
 "jurisdictions": [
  {
   "slug": "las-vegas",
   "name": "Las Vegas",
   "state": "NV",
   "evac_mph": null,
   "evac_text": null,
   "anchorage_text": "Tents and their appurtenances shall be designed and installed to withstand the elements of weather and prevent collapsing; documentation of structural stability shall be furnished to the fire code official (IFC text as printed by Las Vegas Fire & Rescue).",
   "ballast_text": null,
   "engineering_text": null,
   "weather_plan_text": null,
   "guidance_text": null,
   "sources": [
    {
     "title": "Las Vegas Fire & Rescue, Tents and other Membrane Structures (2024)",
     "url": "https://files.lasvegasnevada.gov/fire-rescue/Tents-and-other-Membrane-Structures-2024-Updated.pdf",
     "quote": "Tents or membrane structures and their appurtenances shall be designed and installed to withstand the elements of weather and prevent collapsing. Documentation of structural stability shall be furnished to the fire code official.",
     "last_verified": "2026-11-22",
     "last_verified_s": "November 22, 2026"
    }
   ]
  },
  {
   "slug": "denver",
   "name": "Denver",
   "state": "CO",
   "evac_mph": null,
   "evac_text": null,
   "anchorage_text": null,
   "ballast_text": null,
   "engineering_text": null,
   "weather_plan_text": null,
   "guidance_text": "Denver's event emergency-action-plan guide lists high winds as a delay or cancellation trigger: “Sustained winds or gusts exceeding safe thresholds for tents, staging, or structures (often 30-40 mph).” It also advises anchoring tents with “stakes, weights, or ballast.” This is planning guidance, not a code threshold.",
   "sources": [
    {
     "title": "Denver Special Events, Event Emergency Action Plan development guide (July 31, 2025)",
     "url": "https://www.denvergov.org/files/assets/public/v/1/special-events/documents/eap-toolkit/eap-form-amp-guide/ncr-event-eap-development-guide_english-final_07.31.2025.pdf",
     "quote": "High Winds: Sustained winds or gusts exceeding safe thresholds for tents, staging, or structures (often 30-40 mph).",
     "last_verified": "2026-11-23",
     "last_verified_s": "November 23, 2026"
    }
   ]
  },
  {
   "slug": "nashville",
   "name": "Nashville",
   "state": "TN",
   "evac_mph": null,
   "evac_text": null,
   "anchorage_text": null,
   "ballast_text": null,
   "engineering_text": null,
   "weather_plan_text": null,
   "guidance_text": null,
   "sources": [],
   "notes": [
    "The Nashville Fire Marshal operational-permits page and the permit-type PDF we opened do not state an anchoring rule or a wind speed. Cells are blank until an official text source is found."
   ]
  },
  {
   "slug": "portland-or",
   "name": "Portland, OR",
   "state": "OR",
   "evac_mph": null,
   "evac_text": null,
   "anchorage_text": "Portland Fire & Rescue: “Structural stability and anchorage of tent is required. Documentation of structural stability is required if requested by fire code official.”",
   "ballast_text": "Portland Parks & Recreation: no stakes in any Portland park except Waterfront Park; “Water barrels, stage weights, concrete block or other suitable materials must be used to secure canopies.” In Waterfront Park, utility locates are required before staking.",
   "engineering_text": null,
   "weather_plan_text": null,
   "guidance_text": null,
   "sources": [
    {
     "title": "Portland Fire & Rescue, Requirements for Use of Outdoor Tents (PF&R #300.08 ROT)",
     "url": "https://www.portland.gov/fire/permits-inspections/documents/30008rot-outdoor-tent-or-membrane-structure-permit/download",
     "quote": "Structural stability and anchorage of tent is required. Documentation of structural stability is required if requested by fire code official.",
     "last_verified": "2026-11-22",
     "last_verified_s": "November 22, 2026"
    },
    {
     "title": "Portland Parks & Recreation, Special Use/Public Event User's Guide for Major & Minor Parks",
     "url": "https://www.portland.gov/parks/documents/special-event-manual-guidelines-major-minor-parks/download",
     "quote": "No stakes are allowed in any Portland park except Waterfront. Water barrels, stage weights, concrete block or other suitable materials must be used to secure canopies",
     "last_verified": "2026-11-22",
     "last_verified_s": "November 22, 2026"
    }
   ]
  },
  {
   "slug": "seattle",
   "name": "Seattle",
   "state": "WA",
   "evac_mph": null,
   "evac_text": "No mph figure. The SFD Tents and Heaters info sheet says: “Smaller tents should be removed during snow and ice accumulation and wind events.”",
   "anchorage_text": "Seattle Fire Code 3103.9: tents “shall be designed and installed to withstand the elements of weather and prevent collapsing,” with documentation on request.",
   "ballast_text": null,
   "engineering_text": "Temporary tents “should not be occupied during periods of snow or ice accumulation unless designed for full structural loading per the Seattle Building Code” (SFD info sheet).",
   "weather_plan_text": null,
   "guidance_text": null,
   "sources": [
    {
     "title": "2021 Seattle Fire Code, Chapter 31 (IFC as amended)",
     "url": "https://www.seattle.gov/documents/Departments/SDCI/Codes/SeattleFireCode/2021SFCChapter31.pdf",
     "quote": "3103.9 Structural stability and anchorage required. Tents or membrane structures and their appurtenances shall be designed and installed to withstand the elements of weather and prevent collapsing. Documentation of structural stability shall be furnished to the fire code official on request.",
     "last_verified": "2026-11-22",
     "last_verified_s": "November 22, 2026"
    },
    {
     "title": "Seattle Fire Department, Tents and Heaters for Outdoor Dining and Activities (info sheet, Apr 28, 2025)",
     "url": "https://www.seattle.gov/documents/Departments/Fire/Business/SFDTentsHeatersInfoSheet.pdf",
     "quote": "Smaller tents should be removed during snow and ice accumulation and wind events.",
     "last_verified": "2026-11-22",
     "last_verified_s": "November 22, 2026"
    }
   ],
   "notes": [
    "Separate from wind: the Permit Threshold Atlas still flags a wording conflict between two SFD sources at exactly 400 sq ft with walls (“more than 400 sq ft” vs “400 square feet or greater”). That flag is unchanged here."
   ]
  },
  {
   "slug": "austin",
   "name": "Austin",
   "state": "TX",
   "evac_mph": null,
   "evac_text": null,
   "anchorage_text": null,
   "ballast_text": null,
   "engineering_text": null,
   "weather_plan_text": null,
   "guidance_text": null,
   "sources": [],
   "notes": [
    "The Austin Fire Department special-events page and tent application we opened do not state an anchoring rule or a wind speed. The UT Austin campus SOP (25 mph removal) applies to university property only and is listed under Other published rules, not as a city rule."
   ]
  },
  {
   "slug": "san-francisco",
   "name": "San Francisco",
   "state": "CA",
   "evac_mph": null,
   "evac_text": null,
   "anchorage_text": "Submittals must show the location and quantity of all water barrels, cement blocks or other anchoring/ballasting devices, plus a detail of the attachment method.",
   "ballast_text": "Minimum 5 lb of ballast per sq ft; up to 14 lb per sq ft may be required by SFFD for site, expected weather and permit duration. Minimum 10 lb per sq ft on Port of San Francisco property, Treasure Island and Yerba Buena Island (concrete blocks on Port property). Minimum 2-inch ratchet straps; ropes are not permitted for attaching the frame to ballast; water barrels completely filled.",
   "engineering_text": "Tents of 5,000 sq ft or more, an approved occupant load of 500 or more, or a 60 ft or wider clear span need a stamped report from a California licensed structural engineer stating the tent is designed, installed and anchored for “a minimum wind force of 80 mph.” That is a design figure, not an evacuation speed.",
   "weather_plan_text": null,
   "guidance_text": null,
   "sources": [
    {
     "title": "SFFD Administrative Bulletin 2.13, Submittal Requirements for Temporary Tents and Membrane Structures (2025)",
     "url": "https://sf-fire.org/media/3961",
     "quote": "Shall provide a minimum of 5 lbs per square foot of ballast. Up to 14-lbs per square foot may be required as determined by SFFD due to site location, weather expected, and duration of permit.",
     "last_verified": "2026-11-22",
     "last_verified_s": "November 22, 2026"
    }
   ]
  },
  {
   "slug": "san-diego-county",
   "name": "San Diego County",
   "state": "CA",
   "evac_mph": 25,
   "evac_text": "“Structural stability and anchorage (documentation waived) shall be installed, and when wind speeds exceed 25 mph, the fabric material shall be removed for safety.” (County Fire temporary tents checklist; applies where San Diego County Fire / CAL FIRE is the fire authority, not the City of San Diego.)",
   "anchorage_text": "Structural stability and anchorage shall be installed (documentation waived on this checklist).",
   "ballast_text": null,
   "engineering_text": null,
   "weather_plan_text": null,
   "guidance_text": null,
   "sources": [
    {
     "title": "San Diego County Fire, Temporary Tents Checklist (2026)",
     "url": "https://www.sandiegocounty.gov/content/dam/sdc/deh/pod/2026-documents/Temporary%20Tents%20Checklist.pdf",
     "quote": "Structural stability and anchorage (documentation waived) shall be installed, and when wind speeds exceed 25 mph, the fabric material shall be removed for safety.",
     "last_verified": "2026-11-22",
     "last_verified_s": "November 22, 2026"
    }
   ]
  },
  {
   "slug": "santa-clara-county",
   "name": "Santa Clara County",
   "state": "CA",
   "evac_mph": null,
   "evac_text": null,
   "anchorage_text": "Tents “shall be designed and installed to withstand the elements of weather and prevent against collapsing” and documentation of structural stability is furnished on request (CFC §3103.8 as quoted in SD&S T-1).",
   "ballast_text": "“Water-filled vessels shall not be used to anchor a tent or membrane structure unless approved and in accordance with the tent or membrane structure manufacturer's load specifications.” [CFC §3103.8.1.1]",
   "engineering_text": null,
   "weather_plan_text": null,
   "guidance_text": null,
   "sources": [
    {
     "title": "Santa Clara County Fire Department, SD&S T-1 Tents, Canopies, and Temporary Membrane Structures (10.13.2026)",
     "url": "https://www.sccfd.org/wp-content/uploads/documents/fire_prevention/standards/Standards%20&%20Specifications%2001082025/SD&S%20T-1%20Tents,%20Canopies,%20and%20Temporary%20Membrane%20Structures%2010.13.2026.pdf",
     "quote": "Water-filled vessels shall not be used to anchor a tent or membrane structure unless approved and in accordance with the tent or membrane structure manufacturer's load specifications.",
     "last_verified": "2026-11-22",
     "last_verified_s": "November 22, 2026"
    }
   ]
  },
  {
   "slug": "new-york-city",
   "name": "New York City",
   "state": "NY",
   "evac_mph": null,
   "evac_text": null,
   "anchorage_text": null,
   "ballast_text": null,
   "engineering_text": "NYC Building Code §3102.7.2: “Tents shall be guyed, supported, and braced to withstand a wind pressure of 10 psf (478.8 Pa) of projected area of the tent.” Poles, guys, stakes and fastenings must resist 20 psf, unless an alternate engineering design is approved.",
   "weather_plan_text": null,
   "guidance_text": null,
   "sources": [
    {
     "title": "2022 NYC Building Code, Chapter 31 Special Construction",
     "url": "https://www.bers.nyc.gov/assets/buildings/codes-pdf/cons_codes_2022/2022BC_Chapter31_SpecConstructionWBwm.pdf",
     "quote": "Tents shall be guyed, supported, and braced to withstand a wind pressure of 10 psf (478.8 Pa) of projected area of the tent.",
     "last_verified": "2026-11-22",
     "last_verified_s": "November 22, 2026"
    }
   ],
   "notes": [
    "The FDNY fire-permit page was not used (see the permit atlas note). No evacuation wind speed is on file."
   ]
  },
  {
   "slug": "chicago",
   "name": "Chicago",
   "state": "IL",
   "evac_mph": null,
   "evac_text": "No citywide number: the applicant's high winds action plan sets it (see weather plan).",
   "anchorage_text": "Permit drawings include anchorage details (by a responsible person for smaller tents; by an Illinois-licensed architect or structural engineer for larger ones).",
   "ballast_text": null,
   "engineering_text": "Tents over 600 sq ft or over 15 ft high need drawings by an Illinois-licensed architect or structural engineer; the required documents for those tents include structural (wind resistance) calculations.",
   "weather_plan_text": "“The high winds action plan must specify the wind speed and time period before arrival of a storm at which the temporary structure must be evacuated, the means by which the permit applicant will monitor weather conditions, and the individual(s) responsible for carrying out evacuation and/or disassembly.”",
   "guidance_text": null,
   "sources": [
    {
     "title": "City of Chicago, Temporary Tent Permitting Procedures",
     "url": "https://www.chicago.gov/city/en/depts/bldgs/supp_info/tempstructures/tents.html",
     "quote": "The high winds action plan must specify the wind speed and time period before arrival of a storm at which the temporary structure must be evacuated",
     "last_verified": "2026-11-22",
     "last_verified_s": "November 22, 2026"
    }
   ]
  },
  {
   "slug": "phoenix",
   "name": "Phoenix",
   "state": "AZ",
   "evac_mph": null,
   "evac_text": null,
   "anchorage_text": "The tent permit application requires documentation of structural stability: “staking plan or ballasting plan, manufacturers specifications, stamped engineering plans or the current IFAI Procedural Handbook for the Safe Installation and Maintenance of Tentage and the IFAI Pullout Capacity of Tent Stakes, ARA ballasting calculations.”",
   "ballast_text": null,
   "engineering_text": null,
   "weather_plan_text": null,
   "guidance_text": null,
   "sources": [
    {
     "title": "Phoenix Fire Department, Tent & Membrane Structure Permit Application",
     "url": "https://www.phoenix.gov/content/dam/phoenix/firesite/fire-prevention/tent_application.pdf",
     "quote": "Documentation of structural stability (staking plan or ballasting plan, manufacturers specifications, stamped engineering plans or the current IFAI Procedural Handbook for the Safe Installation and Maintenance of Tentage and the IFAI Pullout Capacity of Tent Stakes, ARA ballasting calculations)",
     "last_verified": "2026-11-23",
     "last_verified_s": "November 23, 2026"
    }
   ]
  },
  {
   "slug": "houston",
   "name": "Houston",
   "state": "TX",
   "evac_mph": null,
   "evac_text": null,
   "anchorage_text": "LSB Standard 22 §22.4.5: tents, canopies and membrane structures “shall be adequately roped, braced, and anchored to withstand the elements of weather and to prevent against collapsing,” with documentation on request.",
   "ballast_text": null,
   "engineering_text": null,
   "weather_plan_text": null,
   "guidance_text": null,
   "sources": [
    {
     "title": "Houston Permitting Center, LSB Standard 22 (Rev. 05)",
     "url": "https://www.houstonpermittingcenter.org/media/9176/download",
     "quote": "Temporary tents, canopies, and membrane structures (air-supported, air-inflated, or tensioned membrane) and their appurtenances shall be adequately roped, braced, and anchored to withstand the elements of weather and to prevent against collapsing.",
     "last_verified": "2026-11-22",
     "last_verified_s": "November 22, 2026"
    }
   ]
  },
  {
   "slug": "boston",
   "name": "Boston",
   "state": "MA",
   "evac_mph": null,
   "evac_text": null,
   "anchorage_text": null,
   "ballast_text": null,
   "engineering_text": null,
   "weather_plan_text": null,
   "guidance_text": null,
   "sources": [],
   "notes": [
    "The 2024 Boston Fire Department tent PDF is a scanned image; our fetch returned no extractable text, so nothing from it is quoted. Cells stay blank until a text-searchable official source is verified."
   ]
  },
  {
   "slug": "los-angeles",
   "name": "Los Angeles",
   "state": "CA",
   "evac_mph": null,
   "evac_text": null,
   "anchorage_text": "The LAFD tent permit asks applicants to provide “Anchoring and structural support details.” No ballast weight or wind speed is stated on that page.",
   "ballast_text": null,
   "engineering_text": null,
   "weather_plan_text": null,
   "guidance_text": null,
   "sources": [
    {
     "title": "Los Angeles Fire Department, Fire Protection Systems: Tent",
     "url": "https://fps.lafd.org/fire-services/tent/",
     "quote": "Anchoring and structural support details",
     "last_verified": "2026-11-23",
     "last_verified_s": "November 23, 2026"
    }
   ]
  },
  {
   "slug": "miami-dade",
   "name": "Miami-Dade County",
   "state": "FL",
   "evac_mph": null,
   "evac_text": null,
   "anchorage_text": "Spacing only: “There shall be a minimum of 12 feet between stake lines (Multiple Tents).” No ballast weight or wind speed is stated in the county brochure.",
   "ballast_text": null,
   "engineering_text": null,
   "weather_plan_text": null,
   "guidance_text": null,
   "sources": [
    {
     "title": "Miami-Dade County, Permitting Membrane Structures brochure",
     "url": "https://www.miamidade.gov/permits/library/brochures/permitting-membrane-structures.pdf",
     "quote": "There shall be a minimum of 12 feet between stake lines (Multiple Tents).",
     "last_verified": "2026-11-22",
     "last_verified_s": "November 22, 2026"
    }
   ]
  }
 ],
 "reference_rules": [
  {
   "who": "Columbia, MO Fire Department (tent/canopy application)",
   "url": "https://webdocs.como.gov/fire/code-enforcement/tent-canopy-application/",
   "evac": "Weighted, non-rated tents and canopies “will not be permitted when winds are forecasted over 20 mph and must be taken down.”",
   "anchor": "Non-rated tents: square footage × 9 psf (“for up to a 30-45 mile-per-hour wind”) = total anchor pounds."
  },
  {
   "who": "University of Texas at Austin Fire Prevention (SOP 102-01, campus only)",
   "url": "https://fireprevention.utexas.edu/sites/default/files/FPS-SOP%20102-01%20Hospitality%20Tents.pdf",
   "evac": "“All tents and canopies shall be removed when wind speeds are expected to exceed 25 mph or greater.”",
   "anchor": "Anchorage calculations for winds up to 20 mph: ballast = tent area × 5 lb/sf × 1.5 safety factor (divide by 0.4 for water barrels)."
  },
  {
   "who": "Livermore-Pleasanton Fire Department, CA (tents up to 1,600 sq ft)",
   "url": "https://lpfire.org/assets/fire-prevention/standards-and-handouts/Tent-Anchorage-Handout-for-Tents-Up-to-1600-sq-feet.pdf",
   "evac": "Tents using the protocol are not used, or are evacuated, if sustained or gust winds exceed 35 mph.",
   "anchor": "7.6 lb per sq ft of tent area in concrete block (“tent industry rule of thumb of providing 10 pounds per square foot of tent area for winds up to 45 miles per hour”)."
  },
  {
   "who": "University of Kentucky Fire Marshal (campus only)",
   "url": "https://fire.uky.edu/temporary-structures",
   "evac": "No tent occupied at sustained winds of 40 mph or more; if the approved maximum is 40 mph or less, vacate at 25 mph or 75% of the rated capacity.",
   "anchor": null
  },
  {
   "who": "City of Tampa, FL (special event park rules)",
   "url": "https://www.tampa.gov/sites/default/files/document/2026/rules-for-special-event-parks_0.pdf",
   "evac": null,
   "anchor": "“No staking of tents”; sandbags or water ballast of at least 40 lbs on each leg, attached to roof and legs separately."
  }
 ],
 "reference_note": "Rules from fire departments and campuses outside the 16 atlas jurisdictions, quoted from the brief's verified sources (checked November 22, 2026). Campus rules apply to that campus only.",
 "url": "https://tentrentalhq.com/tent-wind-rules/"
}