Event tent planner: size, permit check and companies that reach your venue
One pin, one form: get a tent size range, a permit check, restroom trailer counts and the listed tent companies near your venue. Free, no sign-up.
Send this plan to local tent companies (free)
Quick reference (works without JavaScript)
| Guests | Rounds (10–12 sq ft) | Banquet (8–10) | Cocktail (6–8) | Restroom minimum (1 per 100) | Accessible units (5%, min 1) |
|---|---|---|---|---|---|
| 50 | 500–600 sq ft | 400–500 sq ft | 300–400 sq ft | 1 | 1 |
| 100 | 1,000–1,200 sq ft | 800–1,000 sq ft | 600–800 sq ft | 1 | 1 |
| 150 | 1,500–1,800 sq ft | 1,200–1,500 sq ft | 900–1,200 sq ft | 2 | 1 |
| 200 | 2,000–2,400 sq ft | 1,600–2,000 sq ft | 1,200–1,600 sq ft | 2 | 1 |
| 250 | 2,500–3,000 sq ft | 2,000–2,500 sq ft | 1,500–2,000 sq ft | 3 | 1 |
| 300 | 3,000–3,600 sq ft | 2,400–3,000 sq ft | 1,800–2,400 sq ft | 3 | 1 |
| 500 | 5,000–6,000 sq ft | 4,000–5,000 sq ft | 3,000–4,000 sq ft | 5 | 1 |
Rules the planner uses
- Tent space per guest: Peak Rentals seating chart (rounds 10–12, banquet 8–10, cocktail 6–8 sq ft per guest).
- Tent permit flag: IFC §3103.2: tent permit over 400 sq ft; open-sided tents up to 700 sq ft can be exempt, as published by the City of Napa. Local rules can be stricter.
- Restroom minimum, 1 per 100 attendees: Maricopa County Environmental Health Code, Ch. II §VI, Reg. 5 (1 toilet per 100 persons at public gatherings); Calvert County, MD Special Event Manual, 2023 (1 portable restroom per 100; one ADA unit or 5%); City of Detroit Special Events Applicant Guide (1 portable restroom per 100 attendees).
- Accessible units: U.S. Access Board, Guide to the ADA Standards, Chapter 6 (portable units: at least 5% of each cluster, §213.2 Exc. 3).
- Companies in reach: listed tent companies within 150 straight-line miles (local within 60 first), with fees only from each company's published terms. Estimates for planning, not quotes.
Questions
How big a tent do I need for my guests?
Plan about 10–12 sq ft per guest for seated dinners at round tables, 8–10 for long banquet tables and 6–8 for cocktail-style events, plus room for a dance floor, buffet, bar or stage (Peak Rentals seating chart). For 150 guests at rounds that is 1,500–1,800 sq ft, which fits a 40x60 frame tent (2,400 sq ft) with room to spare.
Do I need a permit for an event tent?
Under International Fire Code §3103.2, as published by the City of Napa, tents over 400 sq ft generally need a permit; open-sided tents up to 700 sq ft can be exempt. Local adoption varies, so ask your fire marshal; tent companies usually file it.
How many restrooms do I need for an outdoor event?
Many counties and cities set a minimum of one toilet per 100 attendees for public events (for example Maricopa County, Calvert County MD and Detroit). If you use portable units, at least 5% of each cluster must be accessible, rounded up (ADA Standards §213.2, Exception 3).
Need restroom trailers? Use the RestroomTrailerHQ.com event planner or browse RestroomTrailerHQ.com, our sister directory of luxury restroom trailer fleets.