Get quotes

Open data

Tent Permit Threshold Atlas

When a tent needs a fire or building permit is a local question. In the cities we have sourced, the walled-tent trigger runs from 200 sq ft (Denver and Nashville) to 1,200 sq ft (Houston). The same 20x20 (400 sq ft) walled tent can need a permit in one city and not in another. Every cell below traces to an official page, last verified November 22, 2026.

On this atlas: 13 jurisdictions with a sourced size trigger, 2 with a blank threshold (Boston, Los Angeles), and 1 with other published rules but no permit-size trigger on file (Miami-Dade). New York City fees are left blank until that source can be re-checked. This is not a permit ledger of issued permits.

Not legal or engineering advice. Thresholds are quoted from the official pages linked here, as last verified on the date shown. Confirm the current rule with the fire marshal or building official who has jurisdiction over your site.

Map of walled-tent triggers

Basemap: © OpenStreetMap contributors. Boundaries: U.S. Census Bureau, 2024 Cartographic Boundary Files (TIGER/Line), 1:500,000. Optional imagery: USDA NAIP via the FPAC ImageServer. No Google Maps data.

The 20x20 / 600 / 1,800 test

Each row applies the published rule to a 400 sq ft walled tent, a 600 sq ft open-sided canopy, and a 1,800 sq ft tent. Where a rule depends on height, clearance or distance to a building, the cell says so instead of guessing.

JurisdictionWalled / tent triggerOpen-sided or canopy20x20 walled (400)20x30 open (600)30x60 (1,800)Lead time / fee (as published)Last verified
Las Vegas, NVOperational permit for a tent in excess of 400 sq ft.Open-on-all-sides tents exempt up to 700 sq ft (individual or aggregate without a 12 ft fire break) with 12 ft clearance.NoNo, if conditions are metYes—November 22, 2026
Denver, COPermits for tents 200 sq ft or larger and canopies 400 sq ft and larger.Canopies 400 sq ft and larger.YesYesYesInitial applications 30 days before the event.November 22, 2026
Nashville, TNTent in excess of 200 sq ft or canopy in excess of 400 sq ft.Canopy in excess of 400 sq ft.YesYesYes—November 22, 2026
Portland, OR, OR400 sq ft or more with 3 or more walls, or any tent 700 sq ft or greater.Any tent or membrane structure with or without walls that is 700 sq ft or greater. Side-by-side tents over 700 sq ft aggregate without a 12 ft fire break also need a permit.YesNoYesA complete application packet must be received no later than 21 calendar days before the use date; late filings may be charged double fees. · $250 (4 days or less) / $375 (5 days to 6 months).November 22, 2026
Seattle, WAMore than 400 sq ft. Roof-only exempt up to 700 sq ft.Roof-only tents exempt up to 700 sq ft.Sources disagree at exactly 400 sq ftNo, if roof-onlyYes30 calendar days to avoid a late fee. Permits last up to 28 days.November 22, 2026
Austin, TX>400 sq ft with one or more sidewalls, >400 sq ft within 20 ft of a building, or any structure >700 sq ft.Any structure greater than 700 sq ft, or greater than 400 sq ft within 20 ft of a building.No, at exactly 400 sq ftNot automaticallyYesDue 10 days before the event (events under 50 people); ACE application 30 days before. · $375 first tent, $75 each additional.November 22, 2026
San Francisco, CABulletin applies to tents in excess of 400 sq ft. Open-sided exempt up to 700 sq ft.Open-sided exempt up to 700 sq ft.NoNo, if open-sidedYes—November 22, 2026
San Diego County, CAMore than 400 sq ft (2022 CFC 3103.2), with the 700 sq ft open-sided exception.Individual tents open on all sides that exceed 700 sq ft, or multiple open-sided tents with an aggregate area more than 700 sq ft if not separated by at least 12 ft.NoNo, if open-sided and separatedYes—November 22, 2026
Santa Clara County, CAAn operational permit is required for a tent having an area in excess of 400 sq ft (2025 CFC §105.5.51).Tents open on all sides are excepted if each is at most 700 sq ft, the aggregate of tents without a 12 ft fire break does not exceed 700 sq ft, and a 12 ft clearance to structures and other tents is provided.NoNo, if the listed conditions are metYes—November 22, 2026
New York City, NYBuilding permit exemption only for tents less than 400 gross sq ft for not more than 30 days.The published exemption is the same for tents under 400 gross sq ft and 30 days or less.Yes (building permit)Yes (building permit)Yes (building permit)—November 22, 2026
Chicago, ILNo building permit at 400 sq ft or less and 15 ft or lower. 401–600 sq ft (≤15 ft) can use drawings by “any responsible person.”The published building-permit path is by area and height, not by walled vs. open-sided.No building permit if 15 ft or lowerYes (simplified drawings if ≤15 ft)Yes—November 22, 2026
Phoenix, AZTents in excess of 800 sq ft or canopies in excess of 1,200 sq ft.Canopies in excess of 1,200 sq ft.NoNoYes$25/day late fee if filed within 10 business days. · Event permits (including tents) minimum 3 hours, $585. $25/day late fee if filed within 10 business days.November 22, 2026
Houston, TXTents, canopies and membrane structures 1,200 sq ft or more.Tents, canopies and membrane structures 1,200 sq ft or more.NoNoYesApplications filed less than 5 days before the event incur a priority inspection fee.November 22, 2026
Boston, MA——Not published hereNot published hereNot published here—November 22, 2026
Los Angeles, CA——Not published hereNot published hereNot published here—November 22, 2026
Miami-Dade County, FL——Permit threshold not published herePermit threshold not published hereFire watch by size; permit threshold not published here—November 22, 2026

City and county pages

Sourced · last verified November 22, 2026

Las Vegas

Operational permit for a tent in excess of 400 sq ft.

20x20 (400 sq ft) walledNo
20x30 (600 sq ft) open-sidedNo, if conditions are met
30x60 (1,800 sq ft)Yes

Official source: Las Vegas Fire & Rescue, Tents and other Membrane Structures (2024). Not legal or engineering advice. Thresholds are quoted from the official pages linked here, as last verified on the date shown. Confirm the current rule with the fire marshal or building official who has jurisdiction over your site.

Sourced · last verified November 22, 2026

Denver

Permits for tents 200 sq ft or larger and canopies 400 sq ft and larger.

20x20 (400 sq ft) walledYes
20x30 (600 sq ft) open-sidedYes
30x60 (1,800 sq ft)Yes

Official source: Denver Fire Department event guidelines. Not legal or engineering advice. Thresholds are quoted from the official pages linked here, as last verified on the date shown. Confirm the current rule with the fire marshal or building official who has jurisdiction over your site.

Sourced · last verified November 22, 2026

Nashville

Tent in excess of 200 sq ft or canopy in excess of 400 sq ft.

20x20 (400 sq ft) walledYes
20x30 (600 sq ft) open-sidedYes
30x60 (1,800 sq ft)Yes

Official source: Nashville Fire Marshal's Office, operational permits. Not legal or engineering advice. Thresholds are quoted from the official pages linked here, as last verified on the date shown. Confirm the current rule with the fire marshal or building official who has jurisdiction over your site.

Sourced · last verified November 22, 2026

Portland, OR

400 sq ft or more with 3 or more walls, or any tent 700 sq ft or greater.

20x20 (400 sq ft) walledYes
20x30 (600 sq ft) open-sidedNo
30x60 (1,800 sq ft)Yes

Official source: Portland Fire & Rescue, outdoor tent or membrane structure permit (300.08 ROT). Not legal or engineering advice. Thresholds are quoted from the official pages linked here, as last verified on the date shown. Confirm the current rule with the fire marshal or building official who has jurisdiction over your site.

Sourced · last verified November 22, 2026

Seattle

More than 400 sq ft. Roof-only exempt up to 700 sq ft.

20x20 (400 sq ft) walledSources disagree at exactly 400 sq ft
20x30 (600 sq ft) open-sidedNo, if roof-only
30x60 (1,800 sq ft)Yes

Official source: Seattle Fire Department, Tents & Flameproofing. Not legal or engineering advice. Thresholds are quoted from the official pages linked here, as last verified on the date shown. Confirm the current rule with the fire marshal or building official who has jurisdiction over your site.

Sourced · last verified November 22, 2026

Austin

>400 sq ft with one or more sidewalls, >400 sq ft within 20 ft of a building, or any structure >700 sq ft.

20x20 (400 sq ft) walledNo, at exactly 400 sq ft
20x30 (600 sq ft) open-sidedNot automatically
30x60 (1,800 sq ft)Yes

Official source: Austin Fire Department, special events. Not legal or engineering advice. Thresholds are quoted from the official pages linked here, as last verified on the date shown. Confirm the current rule with the fire marshal or building official who has jurisdiction over your site.

Sourced · last verified November 22, 2026

San Francisco

Bulletin applies to tents in excess of 400 sq ft. Open-sided exempt up to 700 sq ft.

20x20 (400 sq ft) walledNo
20x30 (600 sq ft) open-sidedNo, if open-sided
30x60 (1,800 sq ft)Yes

Official source: San Francisco Fire Department Bulletin 2.13 (2025). Not legal or engineering advice. Thresholds are quoted from the official pages linked here, as last verified on the date shown. Confirm the current rule with the fire marshal or building official who has jurisdiction over your site.

Sourced · last verified November 22, 2026

San Diego County

More than 400 sq ft (2022 CFC 3103.2), with the 700 sq ft open-sided exception.

20x20 (400 sq ft) walledNo
20x30 (600 sq ft) open-sidedNo, if open-sided and separated
30x60 (1,800 sq ft)Yes

Official source: San Diego County Temporary Tents Checklist (2026 documents). Not legal or engineering advice. Thresholds are quoted from the official pages linked here, as last verified on the date shown. Confirm the current rule with the fire marshal or building official who has jurisdiction over your site.

Sourced · last verified November 22, 2026

Santa Clara County

An operational permit is required for a tent having an area in excess of 400 sq ft (2025 CFC §105.5.51).

20x20 (400 sq ft) walledNo
20x30 (600 sq ft) open-sidedNo, if the listed conditions are met
30x60 (1,800 sq ft)Yes

Official source: Santa Clara County Fire Department Standard T-1 (dated 10.13.2026 in the file name). Not legal or engineering advice. Thresholds are quoted from the official pages linked here, as last verified on the date shown. Confirm the current rule with the fire marshal or building official who has jurisdiction over your site.

Sourced · last verified November 22, 2026

New York City

Building permit exemption only for tents less than 400 gross sq ft for not more than 30 days.

20x20 (400 sq ft) walledYes (building permit)
20x30 (600 sq ft) open-sidedYes (building permit)
30x60 (1,800 sq ft)Yes (building permit)

Official source: 2022 NYC Building Code, Chapter 31. Not legal or engineering advice. Thresholds are quoted from the official pages linked here, as last verified on the date shown. Confirm the current rule with the fire marshal or building official who has jurisdiction over your site.

Sourced · last verified November 22, 2026

Chicago

No building permit at 400 sq ft or less and 15 ft or lower. 401–600 sq ft (≤15 ft) can use drawings by “any responsible person.”

20x20 (400 sq ft) walledNo building permit if 15 ft or lower
20x30 (600 sq ft) open-sidedYes (simplified drawings if ≤15 ft)
30x60 (1,800 sq ft)Yes

Official source: Chicago Department of Buildings, temporary tent procedures. Not legal or engineering advice. Thresholds are quoted from the official pages linked here, as last verified on the date shown. Confirm the current rule with the fire marshal or building official who has jurisdiction over your site.

Sourced · last verified November 22, 2026

Phoenix

Tents in excess of 800 sq ft or canopies in excess of 1,200 sq ft.

20x20 (400 sq ft) walledNo
20x30 (600 sq ft) open-sidedNo
30x60 (1,800 sq ft)Yes

Official source: Phoenix, outdoor events / temporary assembly permits. Not legal or engineering advice. Thresholds are quoted from the official pages linked here, as last verified on the date shown. Confirm the current rule with the fire marshal or building official who has jurisdiction over your site.

Sourced · last verified November 22, 2026

Houston

Tents, canopies and membrane structures 1,200 sq ft or more.

20x20 (400 sq ft) walledNo
20x30 (600 sq ft) open-sidedNo
30x60 (1,800 sq ft)Yes

Official source: Houston Fire Department LSB Standard 22, Rev. 05 (effective 1/1/2024). Not legal or engineering advice. Thresholds are quoted from the official pages linked here, as last verified on the date shown. Confirm the current rule with the fire marshal or building official who has jurisdiction over your site.

Threshold not yet published · last verified November 22, 2026

Boston

No official size threshold on file.

20x20 (400 sq ft) walledNot published here
20x30 (600 sq ft) open-sidedNot published here
30x60 (1,800 sq ft)Not published here

Official source: City of Boston, Tents 2024 PDF. Not legal or engineering advice. Thresholds are quoted from the official pages linked here, as last verified on the date shown. Confirm the current rule with the fire marshal or building official who has jurisdiction over your site.

Threshold not yet published · last verified November 22, 2026

Los Angeles

No official size threshold on file.

20x20 (400 sq ft) walledNot published here
20x30 (600 sq ft) open-sidedNot published here
30x60 (1,800 sq ft)Not published here

Official source: LADBS, Application for Temporary Special Event Permit (IN-APP-08). Not legal or engineering advice. Thresholds are quoted from the official pages linked here, as last verified on the date shown. Confirm the current rule with the fire marshal or building official who has jurisdiction over your site.

Partial (no permit-size trigger on file) · last verified November 22, 2026

Miami-Dade County

No official size threshold on file.

20x20 (400 sq ft) walledPermit threshold not published here
20x30 (600 sq ft) open-sidedPermit threshold not published here
30x60 (1,800 sq ft)Fire watch by size; permit threshold not published here
  • Fire watch is required if a tent exceeds 1,600 sq ft or is within 100 ft of buildings.
  • Tents must be 25 ft from streets and 30 ft from property lines.

Official source: Miami-Dade County, permitting membrane structures brochure. Not legal or engineering advice. Thresholds are quoted from the official pages linked here, as last verified on the date shown. Confirm the current rule with the fire marshal or building official who has jurisdiction over your site.

Download and cite

Related: Tent permits and fire code by size · NFPA 701 certificates.

What this atlas does not include