Most fire codes tell you a tent must not fall down. Very few say when to clear it. We read the official pages for the 16 cities and counties in our permit atlas and quoted what each one actually writes about stakes, ballast and wind.

Updated . 22 of 80 cells are filled from official text; 58 are blank because we found no official wording.

Short answer: only one atlas jurisdiction publishes a take-down wind speed — San Diego County Fire, at 25 mph for fabric. Chicago makes each applicant set its own number in a high winds action plan. San Francisco is the only one that writes down a ballast weight (5–14 lb per sq ft). Everywhere else, the code says “withstand the elements of weather,” and the manufacturer's specifications and the fire official on site decide.

Not legal or engineering advice and not an anchoring calculator. Rules are quoted from the official pages linked, as last verified on the date shown. A blank cell means we found no official text, not that no rule exists. Your installer's manufacturer specifications and the fire official on site decide.

The matrix

Read across: a dash means we did not find an official sentence for that column, not that the city has no rule. 12 of 16 rows have at least one sourced cell; 1 has a published take-down speed. City names link to the matching row of the permit threshold atlas.

JurisdictionTake-down / evacuation windAnchoring ruleBallast or no-stake ruleEngineering / design loadWeather planOfficial source
Las Vegas, NV—Tents and their appurtenances shall be designed and installed to withstand the elements of weather and prevent collapsing; documentation of structural stability shall be furnished to the fire code official (IFC text as printed by Las Vegas Fire & Rescue).———Las Vegas Fire & Rescue, Tents and other Membrane Structures (2024) (November 22, 2026)
Denver, CONo code figure; planning guidance below————Denver Special Events, Event Emergency Action Plan development guide (July 31, 2025) (November 23, 2026)
Nashville, TN——————
Portland, OR—Portland Fire & Rescue: “Structural stability and anchorage of tent is required. Documentation of structural stability is required if requested by fire code official.”Portland Parks & Recreation: no stakes in any Portland park except Waterfront Park; “Water barrels, stage weights, concrete block or other suitable materials must be used to secure canopies.” In Waterfront Park, utility locates are required before staking.——Portland Fire & Rescue, Requirements for Use of Outdoor Tents (PF&R #300.08 ROT) (November 22, 2026)
Portland Parks & Recreation, Special Use/Public Event User's Guide for Major & Minor Parks (November 22, 2026)
Seattle, WANo mph figure. The SFD Tents and Heaters info sheet says: “Smaller tents should be removed during snow and ice accumulation and wind events.”Seattle Fire Code 3103.9: tents “shall be designed and installed to withstand the elements of weather and prevent collapsing,” with documentation on request.—Temporary tents “should not be occupied during periods of snow or ice accumulation unless designed for full structural loading per the Seattle Building Code” (SFD info sheet).—2021 Seattle Fire Code, Chapter 31 (IFC as amended) (November 22, 2026)
Seattle Fire Department, Tents and Heaters for Outdoor Dining and Activities (info sheet, Apr 28, 2025) (November 22, 2026)
Austin, TX——————
San Francisco, CA—Submittals must show the location and quantity of all water barrels, cement blocks or other anchoring/ballasting devices, plus a detail of the attachment method.Minimum 5 lb of ballast per sq ft; up to 14 lb per sq ft may be required by SFFD for site, expected weather and permit duration. Minimum 10 lb per sq ft on Port of San Francisco property, Treasure Island and Yerba Buena Island (concrete blocks on Port property). Minimum 2-inch ratchet straps; ropes are not permitted for attaching the frame to ballast; water barrels completely filled.Tents of 5,000 sq ft or more, an approved occupant load of 500 or more, or a 60 ft or wider clear span need a stamped report from a California licensed structural engineer stating the tent is designed, installed and anchored for “a minimum wind force of 80 mph.” That is a design figure, not an evacuation speed.—SFFD Administrative Bulletin 2.13, Submittal Requirements for Temporary Tents and Membrane Structures (2025) (November 22, 2026)
San Diego County, CA“Structural stability and anchorage (documentation waived) shall be installed, and when wind speeds exceed 25 mph, the fabric material shall be removed for safety.” (County Fire temporary tents checklist; applies where San Diego County Fire / CAL FIRE is the fire authority, not the City of San Diego.)Structural stability and anchorage shall be installed (documentation waived on this checklist).———San Diego County Fire, Temporary Tents Checklist (2026) (November 22, 2026)
Santa Clara County, CA—Tents “shall be designed and installed to withstand the elements of weather and prevent against collapsing” and documentation of structural stability is furnished on request (CFC §3103.8 as quoted in SD&S T-1).“Water-filled vessels shall not be used to anchor a tent or membrane structure unless approved and in accordance with the tent or membrane structure manufacturer's load specifications.” [CFC §3103.8.1.1]——Santa Clara County Fire Department, SD&S T-1 Tents, Canopies, and Temporary Membrane Structures (10.13.2026) (November 22, 2026)
New York City, NY———NYC Building Code §3102.7.2: “Tents shall be guyed, supported, and braced to withstand a wind pressure of 10 psf (478.8 Pa) of projected area of the tent.” Poles, guys, stakes and fastenings must resist 20 psf, unless an alternate engineering design is approved.—2022 NYC Building Code, Chapter 31 Special Construction (November 22, 2026)
Chicago, ILNo citywide number: the applicant's high winds action plan sets it (see weather plan).Permit drawings include anchorage details (by a responsible person for smaller tents; by an Illinois-licensed architect or structural engineer for larger ones).—Tents over 600 sq ft or over 15 ft high need drawings by an Illinois-licensed architect or structural engineer; the required documents for those tents include structural (wind resistance) calculations.“The high winds action plan must specify the wind speed and time period before arrival of a storm at which the temporary structure must be evacuated, the means by which the permit applicant will monitor weather conditions, and the individual(s) responsible for carrying out evacuation and/or disassembly.”City of Chicago, Temporary Tent Permitting Procedures (November 22, 2026)
Phoenix, AZ—The tent permit application requires documentation of structural stability: “staking plan or ballasting plan, manufacturers specifications, stamped engineering plans or the current IFAI Procedural Handbook for the Safe Installation and Maintenance of Tentage and the IFAI Pullout Capacity of Tent Stakes, ARA ballasting calculations.”———Phoenix Fire Department, Tent & Membrane Structure Permit Application (November 23, 2026)
Houston, TX—LSB Standard 22 §22.4.5: tents, canopies and membrane structures “shall be adequately roped, braced, and anchored to withstand the elements of weather and to prevent against collapsing,” with documentation on request.———Houston Permitting Center, LSB Standard 22 (Rev. 05) (November 22, 2026)
Boston, MA——————
Los Angeles, CA—The LAFD tent permit asks applicants to provide “Anchoring and structural support details.” No ballast weight or wind speed is stated on that page.———Los Angeles Fire Department, Fire Protection Systems: Tent (November 23, 2026)
Miami-Dade County, FL—Spacing only: “There shall be a minimum of 12 feet between stake lines (Multiple Tents).” No ballast weight or wind speed is stated in the county brochure.———Miami-Dade County, Permitting Membrane Structures brochure (November 22, 2026)

Notes on blank and flagged rows

Planning guidance (not code)

Three different numbers, often confused

  1. Design load. What the installed tent must resist. NYC's building code writes 10 psf of wind pressure on the tent; San Francisco wants an engineer's report at 80 mph for very large tents. Nobody is meant to stay inside at those speeds.
  2. Ballast or stakes. How it is held down. San Francisco's 5 lb per sq ft floor on a 40x60 is 12,000 lb before SFFD asks for more. Ask the installer for the ballast plan in writing when the site cannot be staked.
  3. Take-down speed. The forecast at which guests go indoors and, often, sidewalls come off. San Diego County Fire: over 25 mph. Chicago: whatever your approved high winds plan says.

Published rules from outside the atlas

Rules from fire departments and campuses outside the 16 atlas jurisdictions, quoted from the brief's verified sources (checked November 22, 2026). Campus rules apply to that campus only.

WhoTake-down / evacuationAnchoring or ballast
Columbia, MO Fire Department (tent/canopy application)Weighted, non-rated tents and canopies “will not be permitted when winds are forecasted over 20 mph and must be taken down.”Non-rated tents: square footage × 9 psf (“for up to a 30-45 mile-per-hour wind”) = total anchor pounds.
University of Texas at Austin Fire Prevention (SOP 102-01, campus only)“All tents and canopies shall be removed when wind speeds are expected to exceed 25 mph or greater.”Anchorage calculations for winds up to 20 mph: ballast = tent area × 5 lb/sf × 1.5 safety factor (divide by 0.4 for water barrels).
Livermore-Pleasanton Fire Department, CA (tents up to 1,600 sq ft)Tents using the protocol are not used, or are evacuated, if sustained or gust winds exceed 35 mph.7.6 lb per sq ft of tent area in concrete block (“tent industry rule of thumb of providing 10 pounds per square foot of tent area for winds up to 45 miles per hour”).
University of Kentucky Fire Marshal (campus only)No tent occupied at sustained winds of 40 mph or more; if the approved maximum is 40 mph or less, vacate at 25 mph or 75% of the rated capacity.—
City of Tampa, FL (special event park rules)—“No staking of tents”; sandbags or water ballast of at least 40 lbs on each leg, attached to roof and legs separately.

The model-code baseline

IFC §3103.9 (numbered 3103.8 in some editions): “Tents or membrane structures and their appurtenances shall be designed and installed to withstand the elements of weather and prevent collapsing.” For air-supported structures, door use is controlled in winds over 50 mph (IFC §3103.10.1). The model fire code sets no evacuation wind speed for ordinary tents. Source: 2021 Seattle Fire Code, Chapter 31 (IFC as amended).

Which months are gustiest?

The rule tells you when to clear the tent. The tent wind calendar shows how often that happens: ten years of hourly airport reports for each of these 16 places, month by month. Chicago O'Hare logs a gust of 25 mph or more in 17% of March hours and 3.4% of July hours.

Questions

At what wind speed does a tent have to come down?

There is no national number. Of the 16 cities and counties in our atlas, only San Diego County Fire writes one into a rule: fabric comes off when wind exceeds 25 mph. Denver's event-planning guide mentions 30–40 mph as a common trigger, as guidance. Chicago makes each permit applicant write its own evacuation speed into a high winds action plan. Elsewhere the installer's manufacturer specifications and the fire official decide. Outside the atlas, published figures run from 20 mph (Columbia, MO, weighted non-rated tents) to 40 mph sustained (University of Kentucky).

How much ballast does a tent need?

San Francisco is the only atlas city that writes a weight down: at least 5 lb per sq ft, up to 14 lb at SFFD's discretion, and at least 10 lb on Port property, Treasure Island and Yerba Buena Island. Livermore-Pleasanton FD uses 7.6 lb per sq ft of concrete block for tents up to 1,600 sq ft. These are local rules, not a formula to apply elsewhere.

Is a tent's wind rating the same as its evacuation speed?

No. A design figure, like San Francisco's 80 mph engineer's report for large tents or New York City's 10 psf wind pressure, describes what the installed structure must resist. The take-down or evacuation speed is the lower number at which people leave. Our wind ratings guide explains the difference.

Can I stake a tent in a city park?

Often not. Portland Parks bans stakes in every park except Waterfront Park and asks for water barrels, stage weights or concrete block. Tampa's special-event parks also ban staking and ask for at least 40 lbs per leg. Ask the park before the installer quotes a pole tent.